logo
Thuis ProductenGassensor

ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices

Certificaat
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaten
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaten
Ik ben online Chatten Nu

ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices

ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices
ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices

Grote Afbeelding :  ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices

Productdetails:
Plaats van herkomst: CN
Modelnummer: Ze08-CH2O
Betalen & Verzenden Algemene voorwaarden:
Min. bestelaantal: 1 stks
Prijs: Onderhandelbaar
Verpakking Details: Standaardverpakking
Levertijd: 5-8 werkdagen
Betalingscondities: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Levering vermogen: 5000 pccs

ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices

beschrijving
Oplossing: ≤ 0,01 ppm Nauwkeurigheid: ± 5% FS
Reactietijd (t₉₀): ≤ 30 seconden Hersteltijd (t₁₀): ≤ 60 seconden
Bedrijfstemperatuur: -10 ° C tot +50 ° C Opslagomstandigheden: -20 ° C tot +60 ° C
Markeren:

electrochemical formaldehyde gas sensor

,

indoor air quality sensor for IAQ monitors

,

smart home formaldehyde gas detector

 

       ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices

 

1. Product Overview:

The ZE08-CH2O is a high-precision electrochemical formaldehyde (CH₂O, also known as formaldehyde) gas sensor, specifically engineered for real-time detection of formaldehyde concentrations in indoor and outdoor air. It integrates advanced electrochemical sensing technology to deliver stable, selective, and low-power performance, making it ideal for applications requiring accurate formaldehyde monitoring—such as indoor air quality (IAQ) assessment and safety systems.

2. Key Features:

  • High Selectivity: Utilizes an electrochemical sensing cell optimized for CH₂O, effectively minimizing interference from common background gases (e.g., CO, CO₂, ethanol, methane, and volatile organic compounds/VOCs like benzene).
  • Low Detection Limit: Capable of detecting trace formaldehyde concentrations, meeting strict indoor air quality monitoring requirements.
  • Linear Output: Provides a linear analog or digital output signal proportional to CH₂O concentration, simplifying data acquisition and processing for microcontrollers (MCUs) or embedded systems.
  • Low Power Consumption: Designed for battery-powered devices (e.g., portable IAQ monitors) with minimal current draw.
  • Compact Form Factor: Small SMD or DIP package enables easy integration into compact devices (e.g., smart air purifiers, wearable sensors).
  • Long-Term Stability: Industrial-grade components and advanced encapsulation technology ensure consistent performance and extended service life under normal operating conditions.
  • Fast Response & Recovery: Rapidly responds to changes in CH₂O concentration and returns to baseline quickly after the gas is removed.

3. Typical Applications:

  • Indoor Air Quality (IAQ) Monitors: Residential, office, or school IAQ devices to detect formaldehyde from furniture, paints, or adhesives.
  • Smart Home Devices: Integration with smart air purifiers, thermostats, or safety hubs to trigger alerts/ventilation when CH₂O exceeds safe levels.
  • Portable Detectors: Handheld devices for homeowners, inspectors, or renters to test indoor formaldehyde concentrations.
  • Industrial Monitoring: Low-concentration CH₂O detection in furniture manufacturing, textile printing, or chemical plants (where formaldehyde is used as a raw material).
  • Medical & Commercial Spaces: Monitoring in hospitals, hotels, or childcare centers to ensure compliance with health and safety standards.

4. Installation & Usage Notes:

  1. Avoid Contamination: Do not install the sensor in areas with heavy dust, oil mist, or corrosive gases (e.g., Cl₂, H₂S, ammonia), as these will damage the sensing cell and cause false readings.
  2. Condensation Prevention: Ensure the operating environment remains non-condensing. Use a moisture barrier or ventilation if installing in high-humidity areas (e.g., bathrooms, kitchens).
  3. Calibration: Always calibrate the sensor before first use and at the recommended interval (6–12 months) using a certified formaldehyde standard gas (e.g., 0.5 ppm CH₂O in air). Uncalibrated sensors may drift over time.
  4. Signal Filtering: For analog output, add a low-pass filter (e.g., 100 Hz RC filter) to reduce electrical noise and stabilize readings.
  5. Power Supply Stability: Use a regulated DC power supply to avoid voltage fluctuations, which can cause output instability.
  6. Preheating Time: Allow the sensor to preheat for 3–5 minutes after power-on to ensure stable baseline readings before taking measurements.

Parameter Category

Parameter Name

Specification

Unit

Remarks

Target Gas & Sensing Principle Target Gas Formaldehyde (CH₂O) - Specialized for CH₂O detection; no cross-sensitivity to common VOCs (e.g., benzene, ethanol)
  Sensing Principle Electrochemical (Three-Electrode Structure: Working/Counter/Reference) - Enhances selectivity and reduces long-term drift
Measurement Performance Detection Range Standard: 0 ~ 1 ppm; Optional: 0 ~ 5 ppm ppm 0~1 ppm for indoor air quality (IAQ); 0~5 ppm for industrial scenarios
  Resolution ≤ 0.01 (for 0~1 ppm range); ≤ 0.05 (for 0~5 ppm range) ppm Minimum detectable concentration change
  Accuracy ±5% FS (at 25℃, 1 atm, 50% RH); ±10% FS (at -10℃/+50℃, 15%/85% RH) - FS = Full Scale; tested with 0.5 ppm CH₂O standard gas
  Response Time (T90) ≤ 30 Seconds Time to reach 90% of stable output signal
  Recovery Time (T10) ≤ 60 Seconds Time to drop to 10% of stable output signal
Electrical Characteristics Power Supply Voltage Option 1: 3.3 ± 0.1 V DC; Option 2: 5.0 ± 0.2 V DC V (DC) Select voltage based on device power design; use regulated power
  Operating Current ≤ 20 mA (typical: 15 mA); Standby Current (optional): ≤ 5 mA mA Low current supports battery-powered portable devices
  Output Signal Type Option 1: Analog (0.4 ~ 2.0 V DC, linear with concentration); Option 2: Digital (UART, 9600 bps, 8N1) - Analog for simple integration; UART for data logging
  Zero Drift (Annual) ≤ 3% FS - In clean air (CH₂O < 0.01 ppm); drift increases in high-humidity environments
Environmental Adaptability Operating Temperature Range -10 ~ 50 Optimal range: 0 ~ 40℃ for best accuracy
  Storage Temperature Range -20 ~ 60 Store in dry, CH₂O-free environment; avoid direct sunlight
  Operating Humidity Range 15 ~ 85 % RH Non-condensing; condensation damages the sensing electrode
  Atmospheric Pressure Range 86 ~ 106 kPa Suitable for low-to-medium altitude areas (≤ 1500 meters)
Mechanical & Physical Specs Housing/Package Type Option 1: SMD (Surface-Mount Device); Option 2: DIP (Dual In-line Package) - SMD for compact devices; DIP for easy prototyping
  Overall Dimensions (L×W×H) SMD: 20 × 16 × 6 mm; DIP: 22 × 18 × 7 mm mm Excludes pins/connectors; refer to 2D drawing for exact size
  Weight SMD: ≤ 5 g; DIP: ≤ 8 g g Net weight (no cables/fittings)
  Gas Intake Mode Diffusion (Passive) - No external pump required; ensure 5+ mm clearance for airflow
Lifespan & Maintenance Typical Operational Lifespan ≥ 2 Years Under normal use (no exposure to CH₂O > FS, no dust/condensation)
  Calibration Interval 6 ~ 12    

 

ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices 0

Contactgegevens
ShenzhenYijiajie Electronic Co., Ltd.

Contactpersoon: Miss. Xu

Tel.: 86+13352990255

Direct Stuur uw aanvraag naar ons (0 / 3000)