logo
Thuis ProductenDe Sensor van het zuurstofgas

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Certificaat
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaten
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaten
Ik ben online Chatten Nu

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices
YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Grote Afbeelding :  YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Productdetails:
Plaats van herkomst: Brittannië
Merknaam: YJJ
Modelnummer: O2-C2
Betalen & Verzenden Algemene voorwaarden:
Min. bestelaantal: 1
Prijs: Onderhandelbaar
Verpakking Details: Palletiseerd
Levertijd: 5-8 dagen
Betalingscondities: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Levering vermogen: 2200

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

beschrijving
Meetbereik: 0 - 30% zuurstofconcentratie Huidige output: 80 - 120 μA
Ladingweerstand: 47 - 100 ohm Reactietijd: T90 (van 20,9% tot 0%) <45 seconden
Bedrijfstemperatuur: -30 aan 55℃ Vochtigheidsbereik: 5 - 95% RH
Drukbereik: 80 - 120 KPa Maat: 20,3 × 23 mm
Markeren:

electrochemical oxygen sensor 0-30% range

,

oxygen alarm device sensor

,

YJJ O2-C2 oxygen sensor

Product Description:

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

 

Features:

Main parameters of the O2-C2 oxygen sensor are as follows:

Measurement range

0 - 30% oxygen concentration

Output signal

Current output: 80 - 120 μA (at 22℃, 20.9% oxygen)

Load resistance: 47 - 100 ohms

Response time

T90 (from 20.9% to 0%) < 45 seconds

Environmental adaptability

Operating temperature: -30 to 55℃

Humidity range: 5 - 95% RH

Pressure range: 80 - 120 kPa

Other features

Size: Φ20.3 × 23mm

Weight: < 18g

Storage period: 6 months (sealed preservation)

Linear error: ±0.6% of the full range

Application fields: Oxygen alarm device, atmosphere analyzer

 

Specifications:

Range 0 - 30 ppm
Sensitivity 1.9 ± 0.8 μA/ppm (at 20℃)
Baseline range -0.2 to 2.5 μA (@20℃)
Response time ≤ 45seconds (T90)

 