Productdetails:
|
| Minimale stroomsnelheid: | <0,5SLPM | Nauwkeurigheid: | ±(1,5% aflezing + 0,2% FS) |
|---|---|---|---|
| Herhaalbaarheid: | ≤ 0,25% FS | Totale machtsconsumptie: | ≤ 50 mW |
| Voeding: | DC 5V ± 5% | Toepasselijke media: | Schone en droge gassen zoals lucht, O₂, N₂ |
| Werkomgeving: | 10 - 55℃ | Contactmateriaal: | PPS |
| Bij normale druk: | 20℃ | ||
| Markeren: | MEMS thermal gas flowmeter medical equipment,Medical air flow sensor 0-100SLPM,Gas mass flowmeter with warranty |
||
Product Description:
YJJ FS1015CL-100-ISO-C MEMS Thermal Gas Mass Flowmeter 0-100SLPM Medical Equipment
Features:
I. Model Explanation
FS1015CL: SiXiang MEMS thermal mass flow series (without split-flow straight-through structure)
100: Range 0 - 100 SLPM (standard liters per minute, at standard pressure and 20°C)
ISO: ISO15mm medical standard cannula interface (commonly used in ventilators)
C: Dual output: 0.5 - 4.5V analog voltage + IIC digital signal
II. Core Electrical & Performance Parameters
Range: 0 - 100 SLPM, range ratio 100:1 (can measure very small flow rates), minimum startup flow rate < 0.5 SLPM
Accuracy: ±(1.5% reading + 0.2% FS); repeatability ≤ 0.25% FS
Power Supply: DC 5V ± 5%, total power consumption ≤ 50mW (low power consumption, built-in power supply in the device) Output
Simulation: 0.5V (0 flow rate) to 4.5V (full scale 100SLPM) linear voltage
Digital: IIC communication, direct connection to microcontroller/PLC for reading mass flow values
Pressure resistance: Maximum pressure resistance 0.2MPa (2bar), normal working pressure loss ≈ 1300Pa (low pressure loss, no overpressure)
Response speed: ≤ 8ms, rapid capture of instantaneous flow rate
Applicable media: Air, O₂, N₂, medical mixed gas, etc. Clean and dry gases without oil, water vapor, dust
Working environment: 10-55℃, contact material PPS, reusable after medical alcohol disinfection
III. Product advantages
Thermal mass flow measurement, no need for temperature and pressure compensation, directly outputs standard mass flow rate (not affected by temperature and pressure fluctuations)
Straight-through without bypass structure, low pressure loss, does not obstruct the gas path; medical ISO15 quick connection, direct insertion and removal for ventilator pipelines
Small zero drift, high stability, not prone to drift in medical equipment during long-term continuous operation
IV. Application purposes
1. Medical equipment (main force)
Respirators / Anesthesia machines: Real-time flow monitoring of oxygen, air-oxygen mixed gas, closed-loop control of oxygen concentration, tidal volume statistics; standard components for ICU, emergency ventilators
Oxygen generators, non-invasive ventilators: Inlet / outlet flow collection, abnormal flow interruption alarm protection
Medical endoscopes, therapeutic gas equipment: Supply gas flow control
2. Industrial laboratories
Gas ratio device: Quantitative ratio of nitrogen and air, precise gas supply in laboratory gas path
Leak detection equipment, gas analyzer: Real-time flow collection of small range gas sources
Environmental smoke pre-treatment, small catalytic combustion test gas path measurement
3. New energy & Automation
Fuel cell hydrogen-air inlet flow monitoring, small combustion equipment gas quantitative monitoring
Specifications:
| 100 | Measurement range 0 - 100 SLPM |
| ISO | 15mm |
| C | Dual output: 0.5 - 4.5V |
| Analog voltage | + IIC digital signal |
| Measurement range | 0 - 100SLPM |
| Range ratio 100 | 1 |
![]()